Server-mode serving study

Offline mode measures a batch ceiling: hand an engine a fixed prompt set, let it run flat out, and read off the best-case energy per token. Server mode asks a different question - what does inference cost when requests arrive over time and the engine has to keep up? It drives a running server with an open-loop arrival process, opens measurement windows once the server reaches steady state, and reports energy and latency at each request rate you sweep.

This tutorial builds a rate sweep on vLLM: the same model and prompts as an offline study, but measured as a live service at several arrival rates. By the end you will have one per-window result bundle per measurement window and know how to read the request log behind it.

The framing matters. Offline answers "how cheap can this get?"; server mode answers "how does cost move as load rises, and where does latency break?" The two are complementary, and they share an energy-per-token definition so you can put them side by side (with one caveat about the pre-window protocol - see Step 6).

Compute time: longer than the offline tutorials. Each rate level warms the server to thermal equilibrium, then measures three consecutive windows at the default 240 s each, so budget roughly 20-30 minutes per rate level on a single A100-class GPU once the vLLM image is pulled. Shorten server.traffic.window_seconds for a quick smoke test (at the cost of measurement quality).

Prerequisites

Server mode at v0.7 runs on vLLM and TensorRT-LLM. Transformers in serving_mode: server is rejected at config validation (see Step 6); this tutorial uses vLLM.

Step 1 - What server mode measures

An offline experiment is one engine lifetime that produces one measured window over a fixed prompt batch. A server experiment is one server lifetime that produces many windows - one measurement window per request rate - driven by traffic that arrives over time.

The unit of measurement is the window: a fixed span during which the server is held at a target arrival rate and steady state, and over which energy and latency are attributed. A rate sweep produces one level per rate, and each level measures several windows so a stability gate can confirm the numbers settled.

Two things move from offline to server mode:

AxisOfflineServer
Workload driverfixed prompt batch, run flat outopen-loop arrival process at a target rate
Measurement unitone window per experimentone window per rate level (several per level)
Latencynot the headlineTTFT / ITL percentiles under load, plus SLO attainment
Pre-window waitidle thermal-floor waitloaded warmup to equilibrium (no idle wait)

The shared energy-per-token, tokens-per-second, and gross/net energy definitions are identical across both modes, so cross-mode comparison is legitimate for those figures. The methodology page covers the measurement model in depth.

Step 2 - Write the study config

Here is a complete, runnable server-mode study. Save it as server-study.yaml.

study_name: tutorial-server-mode

serving_mode: server

engine: vllm # single serving engine for this study

runners:
vllm: container

study_execution:
n_cycles: 1
experiment_order: interleave

task:
model: Qwen/Qwen2.5-0.5B
random_seed: 42
dataset:
source: aienergyscore
n_prompts: 200
order: interleaved
max_input_tokens: 256
max_output_tokens: 256

measurement:
energy_sampler: auto
baseline:
enabled: true
duration_seconds: 30.0

server:
traffic:
rate: 2 # base placeholder; the sweep below sets it per cell
arrival: poisson # memoryless arrivals (CV=1)
# window_seconds unset -> defaults to 240s
# ramp_exclusion_seconds unset -> defaults to 30s
warmup:
mode: composite # wait for the thermal-equilibrium gate (default)

sweep:
server.traffic.rate: [2, 4, 8]

output:
results_dir: ./results
save_timeseries: true

Walking through the server-specific parts:

serving_mode: server is required and selects the online-serving measurement path. It is a conditioning identity axis, so a server cell and an offline cell never deduplicate together.

server.traffic is the arrival spec. rate is requests per second; arrival: poisson gives memoryless arrivals (set arrival: gamma with a burstiness value for bursty traffic). Leaving window_seconds unset takes the 240 s default measured-span duration, and leaving ramp_exclusion_seconds unset takes the 30 s default ramp that is excluded from the span. Both defaults are grounded in the minimum-window-duration study.

server.warmup.mode: composite is the default: the harness warms the server with traffic at the target rate and opens the window only once the GPU reaches thermal equilibrium (with a 900 s failsafe). mode: fixed warms for a fixed duration_seconds (default 300 s) instead. See the methodology page for the gate semantics.

sweep: server.traffic.rate: [2, 4, 8] is an ordinary study-level list axis: it expands to three independent measurement cells, one per rate, each with a distinct config hash. The base rate: 2 is a placeholder the sweep overrides.

The full field reference is on the study config reference page (server section, warmup, traffic, and SLO tables).

Step 3 - Dry-run and launch

Resolve the sweep before running anything:

llem run server-study.yaml --dry-run

You should see three resolved cells, one per rate. Because this study uses experiment_order: interleave and n_cycles: 1, the three cells fold into a single server launch that is reused across the sweep - the loader logs an INFO hint if you pick an order that would launch a fresh server per cell instead (see Step 6).

When the counts match your expectation, launch the run:

CLI

llem run server-study.yaml

Python

from llenergymeasure import run_study

study_result = run_study("server-study.yaml")
print(f"Completed {study_result.summary.completed} cells")

Step 4 - What happens at run time

A server session is one server lifetime; under this tutorial's interleave order one session serves all three rate cells as levels over a single launch. Inside a session the harness runs a fixed sequence:

  1. Launch. The engine server starts in a container: the harness allocates a free loopback port and runs the image detached (no --rm, so a crash-on-startup container survives for docker logs).
  2. Readiness probe. A liveness poll of the server's /health endpoint is necessary but never sufficient; readiness is only satisfied once a real inference request driven through the serving path returns HTTP 200.
  3. Warmup. The harness drives issuer traffic at the level's target rate, drawn from the same request-shape distribution the measurement will use. In composite mode it opens the window only once all three equilibrium observables hold at once - GPU power plateaued, temperature settled, and no active thermal throttle - with a 900 s failsafe that proceeds (stamping timed_out) rather than hanging. Warmup re-runs before every rate level.
  4. Ramp exclusion. When load begins for a level, the first 30 s (default) is excluded from the measured span prospectively - it is never trimmed retroactively.
  5. Measurement windows. The harness holds the rate and measures three consecutive windows of 240 s each (defaults). A per-level stability gate checks that per-window energy per token is stable across the windows.
  6. Drain. After the windows close, in-flight requests are drained to completion so latency percentiles include their real end-to-end times; energy accounting never extends into the drain.
  7. Teardown. The server is shut down (docker stop then a force-remove) so nothing leaks, even on the error path.

A rate sweep repeats steps 4-6 per level within the one launched server (under interleave), with an optional inter-level cooldown (server.cooldown_seconds, default 0).

Step 5 - Inspect the per-window results

A server cell produces one result bundle per measurement window. The study directory looks like this:

results/tutorial-server-mode_2026-05-07T14-32-08/
├── manifest.json
├── 001_c0_Qwen2.5-0.5B-vllm_<hashA>/ # rate 2, window 0
│ ├── result.json # window metrics (serving_mode: server)
│ ├── config.json # resolved config + provenance
│ ├── system.json # environment + session facts
│ └── requests.parquet # per-window request log
├── 001_c0_Qwen2.5-0.5B-vllm_<hashA>_1/ # rate 2, window 1 (collision suffix)
├── 001_c0_Qwen2.5-0.5B-vllm_<hashA>_2/ # rate 2, window 2
├── 001_c0_Qwen2.5-0.5B-vllm_<hashB>/ # rate 4, window 0
├── 001_c0_Qwen2.5-0.5B-vllm_<hashB>_1/ # rate 4, window 1
├── 001_c0_Qwen2.5-0.5B-vllm_<hashC>/ # rate 8, window 0
└── ... # nine bundles total: three rates x three windows

All nine bundles share the 001_c0_Qwen2.5-0.5B-vllm_ prefix, because this study interleaves a single server launch across the sweep: the config hash differs per rate, and the second and third window of each rate take a _1 / _2 collision suffix.

Each window's result.json carries serving_mode: "server" and the shared energy metrics; server-distinct metrics (TTFT/ITL percentiles, goodput, SLO attainment) live in the derived server-metrics block, and mode-inapplicable fields (input_tokens, total_tokens) are null because server mode counts client-side streamed output tokens as the canonical denominator. The requests.parquet sidecar is the raw per-request log behind those metrics - one row per issued request, with its own physical facts (issue time, first-token time, terminal status, client-counted output tokens). See the results schema reference for the full column set and how the window results roll up into the study manifest.

A quick read of one window's request log with DuckDB:

import duckdb

rows = duckdb.sql("""
SELECT status, count(*) AS n, median(ttft_ms) AS p50_ttft_ms
FROM 'results/tutorial-server-mode_2026-05-07T14-32-08/*/requests.parquet'
WHERE in_measurement_window AND NOT is_ramp
GROUP BY status
""").df()
print(rows)

Step 6 - Rules to know at v0.7

Server mode is new in v0.7, and a few staging restrictions apply.

  • One serving_mode per study. A single study must be all offline or all server; a mixed study is rejected at config load. Mixed-mode studies arrive in a later release. Run one study per mode for now.
  • A rate list is a sweep axis. server.traffic.rate: [2, 4, 8] expands to independent measurement cells with distinct config hashes - it is not a single multi-rate run.
  • Launch economics depend on experiment order. Consecutive same-cycle cells that differ only by rate fold into one server launch. Under interleave (used here) each sweep pass reuses a single launch. Under the default sequential order with n_cycles > 1, each cell's cycles are adjacent, so the sweep launches a fresh server per cell per cycle; the loader emits an INFO hint suggesting interleave when it detects this.
  • Transformers server mode is rejected. At v0.7 the server engines are vLLM and TensorRT-LLM. serving_mode: server with engine: transformers fails at config validation: the pinned transformers serve is positioned for evaluation and moderate load, not the sustained load a measurement harness drives. A transformers server adapter is a tracked fast-follow (issue #896).
  • Windows are duration-grounded. server.traffic.window_requests (count-bound windows) is rejected at v0.7; use window_seconds.

What you've learned and where to go next

You've now run the server-mode workflow end to end:

  • Framed a serving measurement as a rate sweep over traffic-driven windows rather than a batch ceiling.
  • Written a server-mode study with an open-loop arrival spec and a composite warmup gate.
  • Understood the run-time sequence: launch, real-probe readiness, loaded warmup, ramp exclusion, measurement windows, drain, teardown.
  • Inspected the per-window result bundles and the request log behind them.

Sister recipes (How-to)

Reference

  • Study config - full server / traffic / warmup / SLO field listing.
  • Results schema - the per-window bundle and requests.parquet columns.

Conceptual depth (Explanation)